|
Build Your Online Product Catalogs?
Product Name: |
Fuji Inverter
|
Supply Ability: |
one million |
Related proudcts |
inverter, fuji, fuji inverter, |
Specifications |
FRN-22G1S |
Price Term: |
|
Port of loading: |
|
Minimum Order |
100 |
Unit Price: |
|
|
With the function of HVAC, 1, power frequency / frequency conversion switch load through the external time series corresponding to the frequency / frequency converter switching frequency converter frequency starting processing. Built in power frequency switching time series are: Fuji standard time sequence and frequency converter automatic switching time series 2. 2, the complete PID control function of the PID control functions, such as temperature, pressure, flow, and other control of the regulator in the "low water stop function", "deviation alarm and absolute value alarm output". PID control over the counter reset function, PID output limiter, integral to maintain / reset signal, making the adjustment of PID control function is more easy. 3, the instantaneous power failure in the starting moment of the power supply can be automatically restarted after the resumption of power. Can choose from the occurrence of an instantaneous frequency of power outages and starting from the 0Hz. When the generator is in a flash, it can choose to use the load inertia of the movement energy to reduce the frequency and continue to run the mode. 4, can realize the inverter remote / panel control mode switch by switching frequency setting 1/ frequency set 2, operation and stop the instruction 1/ operation and stop instruction 2 and local operation (operation panel operation), not only can switch operation instruction, frequency instruction, also can switch remote / panel control mode. 5, can achieve a variety of frequency setting method can be used in conjunction with the frequency set signal, select the most appropriate frequency setting method. Operation panel running arrows down arrow keys, analog input (4-20mA, 0-+5V, 0-+10V, +1-+5V, forward / reverse action), multi step frequency step 8 (0-7) setting, up / down, communication and so on. 6, idling motor during the introduction of even in natural convection causes the motor idling, can also through the ***ection of operating frequency and start smoothly. 7, the lower limit of t |
Company: |
Shenzhen City, chuan Energy Automation Co., Ltd
|
Contact: |
Mr. Tang dongdong |
Address: |
BAOBAN XIXIANGSHREET |
Postcode: |
|
Tel: |
86-755-29469509 |
Fax: |
86-755-29469509 |
E-mail: |
|
|
|
|